Simulink simulation error. Conflict with 2 different dimensons

16 visualizaciones (últimos 30 días)
Elvir
Elvir el 22 de Nov. de 2023
Comentada: Rohan Chaudhari el 2 de En. de 2024
I have created a battery system. The battery itself was created using the 'Battery Builder' app. I have now simulated the whole thing and I get the following error message.
The input signal to 'Input Port 2' of subsystem 'untitled/SOC Estimator (Adaptive Kalman Filter)' has a size of 360 for dimension 1. Given the partition width 1 and the partition offset 0 for this input, subsystem 'untitled/SOC Estimator (Adaptive Kalman Filter)' requires 360 iterations. This requirement conflicts with 1, the number of iterations expected by another input/output signal of this subsystem.
Error in port widths or dimensions. 'Output Port 1' of 'untitled/SOC Estimator (Adaptive Kalman Filter)/CellVoltage' is a [360x1] matrix.
Does anyone have an idea how I can solve the problem with the different dimensions without affecting the mathematical calculations?

Respuestas (1)

Fangjun Jiang
Fangjun Jiang el 22 de Nov. de 2023
Double click the "For Each" block and check the mark for partition for input "Current". All other inputs are partitioned but not the "Current" input. It looks it should be partitioned.
  6 comentarios
Elvir
Elvir el 29 de Nov. de 2023
"I apologize for the late response, but I was occupied with other matters. In case you're interested, I resolved my issue over the weekend. Initially, I had to enable the partition in the 'For Each' block of the SOC Estimator (as you've said). Then, in the settings of the SOC Estimator, I had to check the box next to 'Specify current input as cell current(s)'. Lastly, I overlooked an important detail. I had set the constant for 'InitialSOC' to 0.8 only for experimental purposes. The problem arose because 'InitialSOC' became a scalar, while the other two inputs, 'CellVoltage' and 'CellTemperature,' were vectors. For the SOC Estimator to function correctly, all three inputs must have the same size. In my case, I had to convert the scalar 0.8 into a vector."
Thank you for your support :)
Rohan Chaudhari
Rohan Chaudhari el 2 de En. de 2024
hii, can you help i have a similar problem with my model.
this is the error i got:
Error:The input signal to 'Input Port 1' of subsystem 'stone/SOC Estimator (Kalman Filter)' has a size of 160 for dimension 1. Given the partition width 1 and the partition offset 0 for this input, subsystem 'stone/SOC Estimator (Kalman Filter)' requires 160 iterations. This requirement conflicts with 1, the number of iterations expected by another input/output signal of this subsystem.
Error:Error in port widths or dimensions. 'Output Port 1' of 'stone/SOC Estimator (Kalman Filter)/Current' is a [160x1] matrix.
please contact me on my email if i am not able to get back: oceans.rohan@gmail.com