How to take out temperature data of one battery cell from battery pack to use it for controller design?
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
SUDEEP SINGH RAWAT
el 14 de Dic. de 2023
Comentada: SUDEEP SINGH RAWAT
el 16 de Dic. de 2023
Hi,
i am in process of designing a battery pack with liquid cooling. I have used pump to flow the coolant inside the battery pack. The pump shall operate above the upper temperature limit value and shut off when the temperature of the battery cell is within limits. But for that, i need temperature of the single cell from the group of cells. Any suggestion in this regard will be highly helpful for me.
PS: This "goto" block name TEMP_CELL is taking all data of 25 cells but i need only 1 cell data and then i fed it to the controller.
0 comentarios
Respuesta aceptada
Fangjun Jiang
el 14 de Dic. de 2023
Use the Selector block. The dialog might be intimidating to some. For your case, change the "Inport port size" from "3" to "25", and change the "Index" column from "[1 3]" to "1" for picking the first cell or "25" for picking the last cell.