Info

La pregunta está cerrada. Vuélvala a abrir para editarla o responderla.

Function-Call generator does not accept Simulink Parameter

1 visualización (últimos 30 días)
Vamsinag Gunti
Vamsinag Gunti el 6 de Feb. de 2019
Cerrada: MATLAB Answer Bot el 20 de Ag. de 2021
Hi Community,
I am using the Value of a Simulink Parameter as the sample time in the function-call generator. However, I am getting the following error:
Error evaluating parameter 'sample time' in 'MyModel/Function-Call Generator'
Caused by:
  • Struct contents reference from a non-struct array object.
For the sample time I use the value of a simulink parameter:
mySimulinkParameter =
Parameter with properties:
Value: 0.0020
CoderInfo: [1×1 Simulink.CoderInfo]
Description: ''
DataType: 'single'
Min: 0.0010
Max: 1
Unit: ''
Complexity: 'real'
Dimensions: [1 1]
I.e, I enter
mySimulinkParameter.Value
as the sample time. However I get the error that I mentioned above. Could someone please explain this error to me?
Thanks in advance.
Best Regards,
Vamsi

Respuestas (1)

Fangjun Jiang
Fangjun Jiang el 6 de Feb. de 2019
It's a parameter so spescify the sample time as mySimulinkParameter.
  2 comentarios
Vamsinag Gunti
Vamsinag Gunti el 6 de Feb. de 2019
Editada: Vamsinag Gunti el 6 de Feb. de 2019
That was the first thing I tried. The block didn't accept the Simulink Parameter. This is the error I get:
Error reported by S-function 'fnccallgen' in 'MyModel/Function-Call Generator': Invalid sample time. Sample time must be a real scalar value or an array of two real values.
Fangjun Jiang
Fangjun Jiang el 6 de Feb. de 2019
Editada: Fangjun Jiang el 6 de Feb. de 2019
It looks like changing the data type from 'single' to be 'auto' or 'double' will eliminate the error. Worth to repor this to the Mathworks. The error does not make sense.

La pregunta está cerrada.

Etiquetas

Productos


Versión

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by