Simulink shows NO warning when goto and from are missinig/not connected.

16 visualizaciones (últimos 30 días)
Rik Bakker
Rik Bakker el 7 de Mayo de 2019
Comentada: Rik Bakker el 10 de Mayo de 2019
Dear all,
Simulink shows no warning when a goto or from flag is not referenced within the model.
Normally a flag appears orange when a connection is missing. (As shown here below)
Knipsel.PNG
But after a few seconds the orange boundaries dissapeare.
Can i fix it somewhere in the settings or is this just a bug in Simulink?
Kind regards,
Rik

Respuestas (1)

Fangjun Jiang
Fangjun Jiang el 7 de Mayo de 2019
configuration parameters -> Diagnostics -> Connectivity -> Unconnected line
  3 comentarios
Fangjun Jiang
Fangjun Jiang el 7 de Mayo de 2019
The orange highlight should stay on all the time as long as they are enabled and the warning or error still exist. check out this
Rik Bakker
Rik Bakker el 10 de Mayo de 2019
This should work.
Unfortunately i can't select the option Analysis > Model Advisor > Display Advisor Checks in Editor. in my model.
2019-05-10 13_14_30-Start.png

Iniciar sesión para comentar.