Why does LinearFMWaveform require integer Sampling Rate / PRF ratios?
    10 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
Does anybody know why the LinearFMWaveform demands that this condition be met:
The quantity (SampleRate ./ PRF) is a scalar or vector that must contain only integers.
I am modeling a radar with a fixed sampling rate and a discrete set of PRFs. But I cannot make side-by-side comparisons when I have to change the sampling rate for each waveform. Does anybody know a way around this behavior?
0 comentarios
Respuestas (1)
  Honglei Chen
    
      
 el 5 de Oct. de 2012
        Hi Michael,
The pulse supposed to repeat itself at the PRF. If the ratio is not an integer, then the waveform cannot be started from the beginning. As a consequence, the LinearFMWaveform also cannot really output one pulse a time because a pulse is not represented by the integer number of points.
This being said, I am very curious about your case here. Would you mind sharing that in such a situation, how you would like the waveform to behave?
Thanks.