How can I change the initial battery charge of the example microgrid in Matlab?
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Christopher Neal
el 21 de Feb. de 2020
Comentada: Christopher Neal
el 21 de Feb. de 2020
Hello, I'm working with the example microgrid that comes with Matlab/Simulink as shown here:
It can be accessed by typing in 'power_microgrid' in the terminal.
The battery charge is initialized to 80%.
How can I change this value to something else, say 90%?
0 comentarios
Respuesta aceptada
Jeremy
el 21 de Feb. de 2020
Editada: Jeremy
el 21 de Feb. de 2020
If you right click on the Battery_Simple_Dynamics subsystem, you can go to Mask -> Look Under Mask. Here, you will see that the state of charge is being computed in this subsystem. The AH*0.2*3600 constant block after changing to AH*0.1*3600 I then see an initial charge state of 90%.
Más respuestas (1)
Fangjun Jiang
el 21 de Feb. de 2020
Right click, Mask, Look under Mask
Find the Constant block showing "AH*0.2*3600". "0.2" is the determing value. Change it to be 0.1 to make the initial SOC as 90%.
0 comentarios